Who this checklist is for
-
Step 1: Document the room before you open a single catalog
-
Step 2: Sort the project into "grow" vs. "general" lighting—they use different logic
-
Step 3: Settle recessed vs. downlight with one clarifying question
-
Step 4: For grow lights, demand the PPFD map. Wattage tells you almost nothing.
-
Step 5: Check the controls before you commit to the fixtures
-
Step 6: Don't let a small order get downgraded
-
Things that bite you after the invoice
-
A note on fit
Who this checklist is for
If you're an office administrator and someone just dropped "sort out the lighting for the facility" on your desk, this is for you. Six steps, roughly in the order I run them.
It doesn't matter whether you're sourcing a grow light for a demo room, flood lights for a loading dock, or a batch of bar chandeliers for a conference space. The process is the same, and the trap doors are the same. The recessed light vs downlight question gets its own step because it confuses more people than anything else on the list.
For context: I'm not a lighting engineer, and I'm not pretending to be one. What I'm decent at is not getting burned on specs that don't match, vendors who go quiet after the invoice clears, and fixtures that look right on paper but don't fit the ceiling void.
Step 1: Document the room before you open a single catalog
This sounds obvious. It isn't, and it's the step most people skip.
Get: ceiling height (and whether the ceiling is drywall, drop tile, or concrete), the existing wiring and voltage, the footprint in square meters, and whether the space will be used for anything living (plants, aquariums, grow areas) or just people. Take photos. Measure the ceiling void depth if you're considering anything recessed—most recessed cans need four to six inches of clearance, and a lot of shallow-ceiling offices can't take them.
Why this matters: you can't evaluate a fixture until you know what it has to fit into. I once ordered recessed fixtures for a client's conference room and only found out at install that the ceiling had less than three inches of clearance. Every fixture went back. Measure first. Always.
Step 2: Sort the project into "grow" vs. "general" lighting—they use different logic
General lighting is sized on lumens (how much light reaches the space), beam angle, and color temperature. Grow lighting is sized on PPFD and spectrum. These two vocabularies don't translate cleanly, and if you mix them up you'll buy the wrong thing.
If the project is a general office or warehouse, you're in lumens territory. A bar chandelier over a reception desk is a design and beam problem, not a spectrum problem. Same for flood lights: you care about coverage area, mounting height, and whether the beam is wide enough for the yard.
If the project involves plants, you're in PPFD territory, and the brand name matters less than the documentation. This is where products like the spider farmer se7000 grow light and similar bar-style fixtures from spider-farmer come up—not because of the logo, but because grow lights in that class usually ship with PPFD maps at multiple hang heights. That documentation is what you actually need to spec a room.
Step 3: Settle recessed vs. downlight with one clarifying question
Here's the part that trips people up: "recessed" describes the installation (the housing sits inside the ceiling). "Downlight" describes the direction (light goes downward). A recessed downlight is the standard bathroom and kitchen can light. But you can also buy surface-mounted downlights that don't sit inside anything.
So the real question isn't "recessed or downlight?" It's "recessed or surface-mounted, and do you need directional?" Ask your stakeholder exactly that:
- Recessed = cleaner look, requires ceiling void, harder to retrofit.
- Surface-mounted = easier install, fits shallow ceilings, less clean visually.
- Downlight pattern = tighter beam, good for task and accent lighting.
- Flood pattern = wider beam, better for general and area illumination.
When I get a vague "we want something like the one in the photo," I send back two clarifying images: a recessed can and a surface-mounted downlight. That single question saves weeks.
Step 4: For grow lights, demand the PPFD map. Wattage tells you almost nothing.
A well-documented grow light—the spider farmer se7000 grow light is a reasonable example—gives you a PPFD map at stated hang heights, a spectrum chart, and a footprint recommendation. If a vendor can't hand those over, they can't help you spec the room.
Per FTC advertising guidelines (ftc.gov), performance claims—including PPFD and spectrum claims—must be truthful and substantiated. In practice that means asking for the test report or datasheet, not the marketing page. "2000 PPFD" on a product listing is not a spec. "1820 µmol/m²/s at 12 inches, center, measured 30 cm below fixture" is a spec.
You also want the photon flux and where it falls off. A wide fixture with even coverage usually beats a hot center with dark corners, especially in a greenhouse or grow tent where the plants move every cycle.
Step 5: Check the controls before you commit to the fixtures
For grow setups, the controller ecosystem matters as much as the lights. If you're buying a spider farmer fan controller alongside LED bars, confirm they speak the same protocol. Some run on 0-10V, some on their own smart controllers, some on Zigbee. Mixing brands at this step is how you end up with two apps, three dongles, and no automation.
For general lighting, dimming protocol is the trap. TRIAC, 0-10V, DALI, and wireless dimming are not interchangeable. A "dimmable" fixture and a "dimmable" wall switch don't automatically get along. Ask the fixture vendor: "What dimming protocol does this driver use, and which specific dimmer have you verified it with?" If they can't name one, you're doing their integration testing for them.
Never expected the control layer to be what blew up the schedule. Turns out the fixtures were fine—the dimmer protocol wasn't compatible with the panel we already had, and we lost two weeks waiting on an adapter.
Step 6: Don't let a small order get downgraded
Part of me gets why vendors push minimums—small orders are real overhead. Another part has been on the receiving end of "we don't really take orders under $500," and I can tell you it stings.
Here's my working policy: I always place a test order first. Two recessed fixtures, one grow light, a single flood light. If the vendor treats a $200 order like it matters, they get the $4,000 order six months later. If they don't return calls until the PO clears $2,000, I don't come back.
Small doesn't mean unimportant. It means you don't know yet. The vendor's behavior on a small order is the best predictor of how they'll behave when something big goes wrong.
Things that bite you after the invoice
A few extras from my own hit list:
- Unit confusion. Lumens vs. lux vs. PPFD vs. PPF. Buyers mix these up constantly. Before comparing two quotes, make sure the units match.
- Driver quality. The LED chip is what gets marketed; the driver is what fails. Ask for the driver brand and warranty. Cheap drivers are the number one cause of premature failure in recessed and surface lighting.
- Clearance rules. Recessed fixtures and downlights have insulation-contact ratings (IC vs. non-IC). Some can't be covered with insulation. Confirm before install, not after.
- "Dimmable" is not a spec. See Step 5.
- Warranty on the driver, not just the fixture. "5-year warranty" often means the housing, not the driver. Read the fine print.
A note on fit
This worked for our office setup—roughly 3,000 square feet, mixed ceiling types, and a small demo grow area. If you're kitting out an actual commercial greenhouse or a 20,000-square-foot warehouse, the buying volume changes the vendor dynamic and you'll want a lighting consultant to spec coverage. I'm not a lighting engineer, and this checklist is meant to get you through ordinary procurement without getting burned—not to replace a lighting design review on a big project.